Vaisala BAROCAP PTB330 Guia do Utilizador Página 123

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 138
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 122
Chapter 7 ____________________________________________________________ Technical Data
VAISALA______________________________________________________________________ 121
Table 26 Relay Module
Operating temperature range -40...+60 °C (-40...+140 °F
Operating pressure range 500...1300 mHg
Power consumption @24 V max 30 mA
Contacts SPDT (change over), for example,
Contact arrangement Form C
Imax 0.5 A 30 VDC
Safety standard for the relay component IEC60950 UL1950
Storage temperature range -55...+80 °C (-67...+176 °F)
3-pole screw terminal / relay
Max wire size
2.5 mm
2
(AWG14)
Table 27 RS-485 Module
Operating temperature range -40...+60 °C (-40...+140 °F)
Operating modes 2-wire (1-pair) half duplex
4-wire (2-pair) full duplex
Operating speed max 115.2 kbaud
Bus isolation 300VDC
Power consumption @ 24V max 50 mA
External loads standard loads 32 RL> 10kohm
Storage temperature range -55...+80 °C (-67...+176 °F)
Max wire size
1.5 mm
2
(AWG16