Chapter 8 ____________________________________________________________ Technical Data
VAISALA______________________________________________________________________ 221
Fuel Moisture/Fuel Temperature
Sensor
Fuel Moisture/Fuel Temperature Sensor uses two analog channels of
the logger: one for temperature measurement and the other for moisture
measurement. Moisture is measured via one of the channels CH1 to
CH3. You should connect the sensor cable to the appropriate channel.
Temperature is measured with one of the channels CH4 to CH7 and
therefore you should modify the wiring as instructed below:
1. Loosen and remove two hand screws beneath the tube. Slide the
tube down to expose the logger.
2. Select one of the analog channels, CH1 ... CH3, and place the
connector to the selected input channel at the logger. The exact
channel depends on your configuration.
3. Remove the connector from the selected temperature measurement
channel, that is, one of the channels CH4 ... CH7. The removed
cables and their connector are not needed. Insert adapter QLA005
to the channel and place the connector on top of it.
0201-040
Figure 164 Adapter Installed to Connector