174 175
HMT365 Humidity and Temperature Transmitter
For high temperatures
12345678910111213141516
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360
5
A
PRICE
Transmitter t
e HMT365 5
2
Parameters
RH+T A
$2,840
RH+T+Td+a+Tw+x D
$3,370
3
Display No display 1
Display on transmitter cover 2
$120
4 Signal Output 2 analog output channels (Ch1 + Ch
4... 20 m
2
Parameter and scaling for No analog output A
analog output (Ch1 & Ch2) RH (0... 100%RH) B B
T (choose range in next section) C C
Td (-40...100°C) (-40...212°F) HH
a (0...500g/m3) (0...218.5gr/ft3) JJ
Tw (0...100°C) (+32...+212°F) KK
x (0...500g/kg d.a) (0...3500gr/lb) LL
Special: Define quantity for: CH1:___________
CH2:________________ XX
Define scale for: CH1:___________
CH2:________________
NOTE:
5
- Td, a, Tw and x are only avalable with parameter selection D Ch1
6
- If only one analog output has been chosen, choose A for Ch2 Ch2
7
Analog output range -20...+80°C (-4...+176°F) D
for temperature -20...+120°C (-4...+248°F) E
-40...+80°C (-40...+176°F) F
- If no temperature output is desired, cho
-40...+120°C (-40...+248°F) G
0...+100°C (+32...+ 212°F) H
-20...+180°C (-4...+356°F) J
-40...+180 °C (-40...+356°F) K
0...+180°C (+32...+356°F) L
Special X
8
Output units Metric 1
Non-metric 2
9
Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A
Conduit fitting NPT1/2" (for wire conduits) B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm C
10
Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2
Factory Mutual (USA) 4
CSA (Canada) 5
TIIS (Japan) 7
11
User's guide No manual A
English B
12 Probe and cable length 2 m cable H
5 m cable J
$160
10 m cable K
$370
13
Sensor type HUMICAP 180 1
HUMICAP 180L2 2
HUMICAP 180R 5
14
A
15 Sensor protection PPS plastic grid & stainless steel netting (recommended cho
DRW0101281SP 1
PPS plastic grid DRW0101276SP 2
Sintered stainless steel filter HM47280SP 3
Stainless steel grid filter HM47453SP 4
16
Probe installation accessories None
0
Mounting flange D
$60
TOTAL
Selections in bold are included in the prices of the basic versions. QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidit
a = Absolute Humidity g/m3 HMT360 5 A 2 2 B C D 2 A 4 B H 5 A 1 D
T = Temperature x = Mixing Ratio g/Kg
Td = Dewpoint Temper
Tw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description Order Code: PRICE
Stahl Zener Barrier (Stahl # 9001/51-280-091-141) $190/channel
(active barrier that requires active input)
Vyniker enclosure $90 each
(enclosure holds 2 barriers)
210665
Transmitter unit
210664
HMT367 Humidity and Temperature Transmitter
For high humidities
12345678910111213141516
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT360
7
A
PRICE
1
Transmitter t
e HMT367 7
2
Parameters RH+T A
$2,840
RH+T+Td+a+Tw+x D
$3,370
3
Display No display 1
Display on transmitter cover 2
$120
4 Signal Output 2 analog output channels (Ch1 + Ch
4... 20 m
2
Parameter and scaling for No analog output A
analog output (Ch1 & Ch2) RH (0... 100%RH) B B
T (choose range in next section) C C
Td (-40...100°C) (-40...212°F) HH
a (0...500g/m3) (0...218.5gr/ft3) JJ
Tw (0...100°C) (+32...+212°F) KK
x (0...500g/kg d.a) (0...3500gr/lb) LL
Special: Define quantity for: CH1:___________
CH2:________________ XX
Define scale for: CH1:___________
CH2:________________
NOTE:
5
- Td, a, Tw and x are only avalable with parameter selection D Ch1
6
- If only one analog output has been chosen, choose A for Ch2 Ch2
7
Analog output range -20...+80°C (-4...+176°F) D
for temperature -20...+120°C (-4...+248°F) E
-40...+80°C (-40...+176°F) F
- If no temperature output is desired, cho
-40...+120°C (-40...+248°F) G
0...+100°C (+32...+ 212°F) H
-20...+180°C (-4...+356°F) J
-40...+180 °C (-40...+356°F) K
0...+180°C (+32...+356°F) L
Special X
8
Output units Metric 1
Non-metric 2
9
Interface cable connection Cable gland M20x1.5 for cable diameters 7.5 ... 12 mm A
Conduit fitting NPT1/2" (for wire conduits) B
Cable gland M20x1.5 for cable diameters 10 ... 15 mm C
10
Ex certification and issuer ATEX 100a 94/9/EC (PTB) 2
Factory Mutual (USA) 4
CSA (Canada) 5
TIIS (Japan) 7
11
User's guide No manual A
English B
12 Probe and cable length 2 m cable V
5 m cable W $160
10 m cable X $370
13
Sensor type HUMICAP 180 1
HUMICAP 180L2 2
HUMICAP 180R 5
14
Reserved for future option A
15 Sensor protection PPS plastic grid & stainless steel netting (recommended choi
DRW0101281SP 1
PPS plastic grid DRW0101276SP 2
Sintered stainless steel filter HM47280SP 3
Stainless steel grid filter HM47453SP 4
16
Probe installation accessories None 0
Duct installation kit B $80
Cable Gland AGRO J $60
Swagelok NPT 1/2" L $60
Swagelok ISO 3/8" M $60
TOTAL
Selections in bold are included in the prices of the basic versions. QTY
Selections in italic are available at an extra price. TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
RH = Relative Humidity a = Absolute Humidity g/m3 HMT360 7A22BCD2A4BV5A1L
T = Temperature x = Mixing Ratio g/Kg
Td = Dewpoint Temper
Tw = Wet Bulb Temperature
NOTE: Intrinsically Safe barriers are required with the HMT360 to achieve a safe installation. The following Stahl barrier is acceptable, if the supply voltage
to the barrier is between 24 - 35 VDC, the cable length between transmitter and barrier is less than 300m, and the external load created by additional
components in the loop is less than 200 ohms. If the installation requirements do not satisfy these parameters, then please consult the HMT360
manual (www.vaisala.com) or contact a manufacturer of safety barriers for additional assistance.
Accessories and Spare Parts : Description Order Code: PRICE
Stahl Zener Barrier (Stahl # 9001/51-280-091-141) $190/channel
(active barrier that requires active input)
Vyniker enclosure $90 each
(enclosure holds 2 barriers)