160 161
Group E: 18.5 mm Diameter, Female Threads
16126HM
16126HM
Metallized membrane filter, 0.5 μm, ø 18.5 mm
Use with: HMP35
Group: E
2787HM
2787HM
Membrane filter, 0.2 microns, ø 18.5 mm
Use with: HMM30, HMP35,HMP45,PTU200,
HMW21/31
Group: E
6597
6597
Plastic grid, 2.5 mm, ø 18.5 mm
Use with: HMM30N,HMP131, HMP35,
HMP45A/D
Group: E
HM46717
HM46717
Plastic grid, 2.5 mm, ø 18.5 mm
Use with: HMP41, HMP45
Group: E
19858HM Membrane filter tube set (5 pcs)
HMP42 aprobe,
0.2 μm, ø 4mm
19867HM Steel grid for the HMP42 probe,
1 mm, ø 4 mm
Stand Alone - Not Interchangeable:
HM46780
Stainless steel filter, 38 μm, ø 20 mm
Use with: DMP246CS - External
HM46780
HM47329
Probe cap, ø 18.5 mm (protective cap)
Use with: HMT100
HM47329
Vaisala Filters continued
HMT331 Humidity and Temperature Transmitter
For wall mounting
1 2 3 4 5 6 7 8 9101112131415161718192021 2223
Vaisala HUMICAP® Humidity and Temperature Transmitter
HMT330 1 A 0 A 1
PRICE
1
Transmitter type HMT331 1
$1,120
2
Cable length
Wall probe fixed
with short cable Probe holder plate recommended in selection 16 8
3
No additional temperature probe 0
4
Parameters RH+T A
RH+T+Td+Tdf+a+x+Tw+ppm+pw+pws+h+dT B $360
5
Display No display 0
Graphic display with keypad
1
$320
6
Power supply 10...35 VDC , 24 VAC (HMT300PWS) 0
Galvanic isolation for outputs 10...35 VDC, 24 VAC
(DcDc-1) 1
$80
Universal AC -power (100....240 VAC)
(Power-1) 2
$200
Universal AC -power (100....240 VAC) + US power cord
(Power-1 and 215991) 3
$210
External US AC-adapter (for LAN/WLAN interface in USA and Canada) Not IP65
9
$60
7
Analog Output Signal 4... 20 mA 1
for Ch1&Ch2(&Ch3) 0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
+ Serial interface RS232 or optional communication module
Analog output signals No 3rd analog output A
for Ch1 , Ch2 and Ch3 RH (0...100%RH) RH=relative humidity BBB
T (range: see below) T=temperature CCC
Td (-20...100°C) (-4...+212 °F) Td=dewpoint DDD
Tdf (-20...100°C) (-4...+212 °F) Tdf = dewpoint/ frost point temperature EEE
a (0...600g/m3) (0...262 gr/ft3)
a=absolute humidity
FFF
Tw (0...100°C) (+32...+212°F) Tw=wet bulb temperature GGG
x (0...500g/kg d.a) (0...3500gr/lb)
x=mixing ratio
HHH
h (-40...1500 kJ/kg) (-9.5...+652.6 Btu/lb)
h=enthalpy JJJ
ppm (0…5000)
(0…5000) ppm=parts per million KKK
pw (0…1000 hPa) (0…14.5psi)
pw=water vapor pressure
LLL
pws (0…1000 hPa) (0…14.5psi) pws=saturation water vapor pressure MMM
dT (-10...+50 °C) (14...+122 °F) dT=(temperature-dewpoint temperature) NNN
SPECIAL Define quantity Ch1:_______________ Ch2:________________ Optional Ch3:______________ X X X
Define scale Ch1:_______________ Ch2:________________ Optional Ch3:______________
8
Channel 1
9
Channel 2
10
Channel 3, choose A if not needed
11
Analog output range No temperature output A
for temperature -40...+60°C
(-40...+140°F)
B
Note:
-20...+60°C
(-4...+140°F)
F
- Choose option A, if no
0...+60°C
(+32...+140°F)
K
T output is desired
Special :_______________________ X
12
Output units Metric 1
Non-metric 2
13
Option for module slot 1 No module 0
Relay output
(Relay-1) 1
$180
RS-485 serial interface (galvanically isolated)
(RS485-1) 2
$160
LAN (Ethernet) interface + 2 m cable (RJ45) Not with universal AC power
4
$260
WLAN (Wireless Ethernet) interface + antenna with short cable probe only
5
$320
Data logger module
6
$350
14
Option for module slot 2 No module 0
Relay output
(Relay-1) 1
$180
3rd Analog output Choose also analog output signal for Ch3
(AOUT-1) 3
$160
Data logger module Not possible if the data logger module has already been chosen in item 11
6
$350
15
Cable bushings Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) A
Conduit fitting for wire conduit (NPT1/2") (214780SP) B
8-pole connector with 5 m cable (not possible with universal AC power option)
(212142)
C $60
8-pole counter connector equipped with screw terminals (not possible with universal AC power option) D $60
16
Transmitter installation Standard wall mounting 0
Adapter plate (for replacing the HMP230's) (214829)
1
$90
Pole installation kit (215108)
2
$100
DIN rail kit (215094)
4
$90
Probe holder plate Recommended with short cable probe (226252)
5
$90
17
Humidity sensor type General purpose HUMICAP180 1
Chemical purge HUMICAP180C
4
$60
General purpose and high chemical concentrations
HUMICAP180R A
Chemical purge HUMICAP180RC C $60
18
Sensor protection
PPS plastic grid & stainless steel netting
(DRW010281SP)
A
PPS plastic grid
(DRW010276SP)
B
Sintered stainless steel filter
(HM47280SP)
C
19
No probe installation kit A
20
Operating manual No manual
A
language English
(M210566EN)
B
21
PC Accessories
No
A
Service cable for PC, RS232
(19446ZZ)
B $40
MI70LINK software for Windows® with RS232 service cable
(215005)
C $60
Service cable for PC, USB with software driver D $90
MI70LINK software for Windows® with USB service cable E $90
22
Calibration
ISO9001 compliant calibration with NIST traceable certificate A
23
For future use 1
TOTAL
Selections in bold are included in the prices of the basic versions.
QTY
Selections in italic are available at an extra price.
TOTAL VALUE
Shaded sections indicate typical selections.
Example of order code with typical settings:
HMT330 1 A 0 A 1 0 1 B C A B 2 0 0 A 0 A A A B A A 1
(212416)
(219685)
(219916)
Order Guides
Order Guides