Vaisala HUMICAP MMT310 Manual de Serviço Página 104

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 123
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 103
188 189
DMT348 Dewpoint and Temperature Transmitter
For Pressurized Pipelines
1 2 3 4 5 6 7 8 9 1011121314151617181920212223
V
aisala DRYCAP® Dewpoint and Temperature Transmitte
r
DMT340 8 0 1 A 0
PRICE
1
Transmitter type
DMT348
8
$2,790
2
Probe Cable lengths 2 m cable (6.6 ft) for standard probe V
5 m cable (16.4 ft) for standardp probe W
$160
10 m cable (32.8 ft) for standard probe X
$370
2 m cable (6.6 ft) for long probe 1
$120
5 m cable (16.4 ft) for long probe 2
$260
10 m cable (32.8 ft) for long probe 3
$460
3
- - 0
4
Measurement Dewpoint + PPM + Mixing ratio (for temperatures below 0° C) A
Parameters Dewpoint + PPM + Mixing ratio + Relative humidity + Temperature (for temperatures above 0° C) B
5
Display No display 0
Graphic Display with Keypad 1 $320
6
Power Supply
10...35 VDC, 24 VA
C
(HMT300PWS) A
10...35 VDC, 24 VAC with Galvanic Isolation for Outputs
(DCDC-1) B $80
Universal AC -power (100....240 VAC)
(Power-1) C $200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991) D $210
External US AC-adapter (for LAN/WLAN interface in USA)
Not IP65 K $60
7
Analog Output Signal 4... 20 mA 1
for Ch1&Ch2(&Ch3) 0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
Analog Output Scaling No 3rd analog output A
for Ch1&Ch2(&Ch3) Dewpoint (-80...+20 °C) ( -112...+68 °F) BBB
Dewpoint (-60...+20 °C) ( -76...+68 °F) CCC
Dewpoint (-50...+50 °C) ( -58...+122 °F) DDD
Temperautre (0...+80 °C
)
(+32...+176 °F) EEE
PPMv (0...1000 ppm) only for channel 1 G
PPMw (0...1000 ppm) only for channel 1 H
Mixing ratio (0...30g/kg d.a) (0...210gr/lbs) JJJ
Relative humidity (0...100%) KKK
SPECIAL Define parameter (unit) for Ch1:_______(_____) Ch2:______(_____) Optional Ch3:________(_____) X X
X
Define scale for Ch1:_____________ Ch2:_____________ Optional Ch3:______________
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11
Operating Pressure 1 bar (abs) (14.5 psi abs) 1
3 bar (43.5) 2
5 bar (72.5) 3
7 bar (101.5) 4
9 bar (130.5) 5
special ( max 50 bar / 725 psi )** (bar / psi)(abs)
X
12
Output Units Metric units A
Non-metric units B
13
Additional Option No Additional Option 0
Alarm Relay Output (Relay-1) 1 $180
RS-485 Serial Interface with Galvanic Isolation
(RS485-1)
2 $160
LAN (Ethernet) interface + 2 m cable (RJ45) 4 $260
WLAN (wireless Ethernet) interface + antenna 5 $320
Data Logger Module
6 $350
14
2nd Additional Option No Additional Option 0
Alarm Relay Output (Relay-1) 1 $180
3rd Analog output Choose also analog output signal for Ch3 (AOUT-1) 3 $160
Data Logger Module Not possible if data logger module has already been chosen in item 11
6 $350
15
User Cable Connection Cable gland (for 8...11mm cable) (for 0.315...0.433 inch cable) (214728SP) 1
Conduit fitting for wire conduit (NPT1/2") (214780SP) 2
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
3
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
4
16
Transmitter Housing Wall Mounting A
Installation Wall Mounting (for adapting to DMP248) (214829) B $90
Pipe/Pole Installation (215108) C $100
Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) D $110
DIN-Rail Installation
(215094) E $90
17
Dewpoint Sensor DRYCAP® 180M 1
18
Sensor Protection Sintered stainless steel filter (HM47280SP) A
Stainless steel filter for vacuum (HM47453SP)
B
19
Probe Installation Fitting body R 1/2" ISO with leak screw
(ISOFITBODASP)
A
Accessories Fitting body R 1/2" ISO ( no leak screw )
(DRW212076SP)
B
Fitting body NPT1/2" ( no leak screw )
(NPTFITBODASP)
C
Two Fitting Bodies: R 1/2" ISO with leak screw + NPT1/2"
(THREADSETASP)
D $25
Sampling Cell
(DMT242SC)
E $80
Sampling Cell with Swagelok connectors
(DMT242SC2)
F $100
Ball Valve Set for Pressurized Pipelines
(DRW212076 + BALVALVE-1)
G $80
Flange for Duct Installation (DM240FA)
H $80
20
User's guide language No manual
A
English
B
21
PC Accessory
No PC Accessorie
s
0
MI70LINK software for Windows® with RS232 service cable (215005) 2
$60
MI70LINK software for Windows® with USB service cable (219916) 4
90
22
Calibration Standard Calibration, with NIST traceable certificate A
23
For future use 0
Selections in bold are included in the prices of the basic version
s
TOTAL
Selections in italic are available at an extra price. QTY
Shaded sections indicate typical selections. TOTAL VALUE
** if measuring in pressures above 20 bara (290 psia) please consult Vaisala sales
Example of order code with typical settings
DMT3408V0B1A1BEA1B001A1ACB0A0
DMT345 Dewpoint Transmitter
For measurement in hot and dry processes
1234567891011121314151617181920212223
Vaisala DRYCAP® Dewpoint Transmitter
DMT340 5 0 B 1 2 A C
PRICE
1
Transmitter type DMT345 5
$3,140
2
Probe cable length 2 m cable (6.6 ft) L
5 m cable (16.4 ft) M
$160
10 m cable (32.8 ft) N
$370
3
- - 0
4
Measurement parameters Dewpoint + mixing ratio + RH+ T
B
5
Display No display 0
Graphical display with keypad 1 $320
6
Power supply
10...35 VDC, 24 VAC
(HMT300PWS) A
10...35 VDC, 24 VAC with galvanic isolation for outputs
(DCDC-1) B $80
Universal AC -power (100....240 VAC)
(Power-1) C $200
Universal AC -power (100....240 VAC) + US -power cord
(Power-1 & 215991) D $210
Ethernet US AC-adapter (for LAN/WLAN intrface in USA) Not IP65 K
$60
7
Analog output 4... 20 mA 1
0... 20 mA 2
0... 1 V 3
0... 5 V 4
0... 10 V 5
Analog output No 3rd analog output A
parameter and scaling
Dewpoint (0...+100 °C) (+32...+212 °F) 1 1 1
for Ch1&Ch2 Mixing ratio (0...1000g/kg) (0...7000gr/lbs) 2 2 2
T (0...140 °C) (+32...284 °F) 3 3 3
RH (0...100 %RH) KKK
SPECIAL Define parameter (unit) for Ch1:________________(_____) Ch2:_______________(_____) X X X
Define scale for Ch1:______________________ Ch2:______________________
8
Channel 1
9
Channel 2
10
Channel 3, choose A, if not needed
11
Operating pressure
ambient
1
12
Output units Metric units A
Non-metric units B
13
Additional feature None 0
Alarm Relay Output (Relay-1) 1 $180
RS-485 Serial Interface with Galvanic Isolation (RS485-1) 2 $160
Data Logging Module
6 $350
14
Additional feature 2 None 0
Alarm Relay Output (Relay-1) 1 $180
3rd analog output (AOUT-1) 3 $160
LAN (ethernet) interface + 2 m cable (RJ45) 4 $260
WLAN (wireless ethernet) interface + antenna 5 $320
Data Logging Module Not possible if the data logger module has already been chosen in item 13
6 $350
15
Interface cable connection Cable gland (for 8...11 mm cable) (for 0.315...0.433 inch cable) (214728SP) 1
Conduit fitting for wire conduit (NPT1/2") (214780SP) 2
Connector (M12, 8 pin) and Plug with 5m Black Cable
(212142)
3 $60
Connector (M12, 8 pin) and Plug for User's Cable
(212416)
4 $60
16
Transmitter housing Wall Mounting A
installation Wall Mounting with Quick Installation or on Junction Boxes (214829) B $90
Pipe/Pole Installation (215108) C $100
Pipe/Pole Installation with Rain Shield for Outdoor Installations (215109) D $110
DIN-Rail Installation
(215094) E $90
17
Sensor
DRYCA
P
®
180S
2
18
Sensor Protection
Stainless steel sintered filter (HM47280SP)
A
19
Probe installation
None 0
Flange (21069)
7 $60
20
User's guide None
A
English
K
21
PC accessories
None
0
MI70LINK software for Windows® with RS232 service cable (215005) 2
$60
MI70LINK software for Windows® with USB service cable (219916) 4
$90
22
Calibration Standard Calibration with NIST traceable certificate C
23
Service contract None 0
Selections in bold are included in the prices of the basic versions. TOTAL
Selections in italic are available at an extra price. QTY
Shaded sections indicate typical selections. TOTAL VALUE
Example of order code with typical settings:
DMT340
5L0B1A113A1B001A2A0K0C0
Vista de página 103
1 2 ... 99 100 101 102 103 104 105 106 107 108 109 ... 122 123

Comentários a estes Manuais

Sem comentários