Appendix A _________________________________ Probe Installation Kits and Installation Examples
VAISALA ______________________________________________________________________ 185
T- Probe Installations (HMT337)
0508-015
Figure 98 Vapor Tight Installation
Vapor Tight Installation is not available from Vaisala.
The following numbers refer to Figure 98:
1 = Cable gland. For example AGRO 1100.12.91.065
(T= -25 ... +200 ºC)
2 = In pressurized processes, use a locking ring
(example: 6x 0.7 DIN471)
0508-022
Figure 99 Wall Mounting Installation
Wall Mounting Installation is not available from Vaisala.
The following numbers refer to Figure 99:
1 =
Cable gland. For example AGRO 1100.12.91.065
2 = Compacted PTFE sleeve
3 = Silicon glue between the PTFE sleeve and the cable
4 = Temperature probe
5 = Recommended support to keep the probe in horizontal
position