Página 1 - PRESSURE / WEATHER

HUMIDITY / DEW POINT / TEMPERATURE / MOISTURE IN OIL / CARBON DIOXIDE / PRESSURE / WEATHER

Página 2 - Measure

8Mixing RatioThe mixing ratio (x) is the ratio of water vapor mass to the mass of dry gas. It is dimensionless but often expressed in grams per kilogr

Página 3

www.vaisala.com98DMT132 Dewpoint Transmitter for Refrigerant Dryers Features / Benefits▪Affordable dew point transmitter for refrigerant dryers▪High a

Página 4 - Dew Point

99Technical DataPerformanceDEW POINTMeasurement range -20 ... +50 °C (-4 ... +122 °F) TdAccuracy (at +20 °C (+68 °F) ±1 °C for -3...20 °C (+26.6 ... +

Página 5

www.vaisala.com100DM70 Hand-Held Dewpoint Meter for Spot-Checking ApplicationsThe Vaisala DRYCAP® Hand-Held Dewpoint Meter DM70 offers accurate and f

Página 6 - Relative Humidity

101Technical DataAccessoriesConnection cables for fixed Vaisala dew point transmittersfor DMT242 transmitter 27160ZZfor DMT340 series 211339for DMT15

Página 7 - Humidity Products

www.vaisala.com102DSS70A Portable Sampling System and Sampling Cells for DM70The DSS70A provides a compact solution for field checking dew point where

Página 8 - Parameters

103Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationDew PointDSS70A Sampling System and

Página 9

www.vaisala.com104DPT146 Dewpoint and Pressure Transmitter for Compressed AirThe DPT146 measures both dew point and process pressure. Monitoring compr

Página 10 - Recommended

105Technical DataDew PointPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationPerformanceDew point accur

Página 11 - Humidity

www.vaisala.com106DPT145 Multiparameter Transmitter for SF6 Gas DPT145 Multiparameter Transmitter for SF6 Gas The Vaisala Multiparameter Transmitter D

Página 12

107Technical DataDew PointPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationAccessories Connection cab

Página 13

960°C the transmitter electronics should be mounted outside the process and only a suitable high temperature probe should be inserted into the high te

Página 14

www.vaisala.com10863.520145.5753.529.5M30x2AW27AW3641.6Dimensional Drawings of the DPT145 Multiparameter Transmitter 8374444 802005259514.830AW8716083

Página 15 - Instruments

[email protected] www.vaisala.com/powerOutages Happen 24/7. So Should Monitoring.• See moisture fluctuations in varying temperature and load cond

Página 16 - Effects of Contaminants

110Moisture in Oil / TECHNOLOGY DESCRIPTIONVaisala HUMICAP® Sensor for Measuring Moisture in OilWater is a common contaminant in industrial oils. Wate

Página 17

111For more information, visitwww.vaisala.com or contact us at [email protected]. B211231EN-A ©Vaisala 2012This material is subject to copyright pr

Página 18

www.vaisala.com112MMT330 Moisture and Temperature Transmitter Series for OilThe Vaisala HUMICAP® Moisture and Temperature Transmitter Series for Oil M

Página 19

113Moisture in OilThe Vaisala HUMICAP® Hand-Held Moisture for Oil Meter MM70 is designed for field-checking MMT330 transmitters.The display alarm allo

Página 20 - Flexible Installation

11497 (3.82)65.5 (2.58) 7 (0.28)35 (1.38)Ø 12 (0.47)9 (0.35)M645°Ø 36 (1.42)16 (0.63)77 (3.03)33 (1.30)NPT1/2"ISO 3/8" or Ø 12 (0.47)Hex 22

Página 21

115Technical DataMoisture in OilMeasured ValuesWATER ACTIVITY Measurement range aw0 ... 1 Accuracy (including non-linearity, hysteresis and repeatabi

Página 22

www.vaisala.com116MMT310 Series Moisture and Temperature Transmitter for OilThe Vaisala HUMICAP® Moisture and Temperature Transmitter Series for Oil

Página 23 - Process is Running

117Technical DataMeasured ValuesWATER ACTIVITYMeasurement range aw0 ... 1Accuracy (including non-linearity, hysteresis and repeatability)0 ... 0.9 ±0.

Página 24 - HMT335 probe

10In a pressurized system a sample pump isn’t needed as the process pressure induces a large enough flow to the sampling cell.When measuring dew point

Página 25 - Measures Up

www.vaisala.com118MMT162 Compact Moisture in Oil and Temperature Transmitter for OEM ApplicationsThe Vaisala HUMICAP® Moisture and Temperature Transmi

Página 26 - Temperature Transmitters

119Technical DataMeasured ValuesWATER ACTIVITYMeasurement range 0 ... 1 awAccuracy (including non-linearity, hysteresis and repeatability)0 ... 0.9 ±

Página 27 - HMP364 for high pressure

www.vaisala.com120MM70 Hand-Held Moisture and Temperature Meter for Spot-Checking in OilThe Vaisala HUMICAP® Hand-held Moisture Meter for Oil MM70 ena

Página 28 - HMP368 for pressurized

121Technical DataRef. B210960EN-C ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indiv

Página 29

122/ TECHNOLOGY DESCRIPTIONVaisala CARBOCAP® Sensor for Measuring Carbon DioxideBox headline hereCARBOCAP in Brief ▪A silicon-based infrared (IR) abso

Página 30

123For more information, visitwww.vaisala.com or contact us at [email protected]. B210780EN-C ©Vaisala 2012This material is subject to copyright pr

Página 31 - Accessories

www.vaisala.com124GMP343 Carbon Dioxide Probe for Demanding MeasurementsThe GMP343 is available as an open-path diffusion-aspirated model (left) and a

Página 32

125Technical DataCarbon DioxidePlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationOperating Environment

Página 33

www.vaisala.com126Dimensional Drawings of the GMP343 Carbon Dioxide ProbeDimensions in mm (inches)552.1752.52.0749146.718131.7451.77552.174249.08814.7

Página 34

127www.vaisala.com/[email protected] built-in reference measurement and robust reliability. Stability is what everyone promises. Bu

Página 35 - Calculate

11Humidity sensors from Vaisala.The Right Humidity Instrument for the JobNo matter what the application, the total range of gas temperatures and expec

Página 36 - Interchangeable Probe

www.vaisala.com128GMT220 Series Carbon Dioxide Transmitters for Industrial Applications The Vaisala CARBOCAP® Carbon Dioxide Transmitter Series GMT220

Página 37

129Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationCarbon DioxidePerformanceMeasuremen

Página 38 - Remote probe dimensions

www.vaisala.com130GMM220 Carbon Dioxide Modules for Demanding OEM ApplicationsFor Harsh EnvironmentsThe Vaisala CARBOCAP® Carbon Dioxide Module Series

Página 39

131Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationCarbon DioxideCarbon DioxideMeasure

Página 40 - BACnet in Brief

www.vaisala.com132GMM111 Carbon Dioxide ModuleThe Vaisala CARBOCAP® Carbon Dioxide Module GMM111 is a CO2 measurement module with flow-through aspirat

Página 41

133Technical DataCarbon DioxideDimensionsDimensions in mmOperating EnvironmentTemperature +5 ... +55 °C (+41 ... +131 °F)Humidity 0 ... 99 %RH non-con

Página 42 - Resistant to Chemicals

www.vaisala.com134GM70 Hand-Held Carbon Dioxide Meter for Spot-Checking ApplicationsThe Vaisala CARBOCAP® Hand-Held Carbon Dioxide Meter GM70 is a use

Página 43

135MI70 Indicator GeneralMenu languages English, Chinese, French, Spanish, German,Japanese, Russian, Swedish, FinnishDisplay LCD with backlight, gr

Página 44

www.vaisala.com136GMW90 Series Carbon Dioxide, Temperature and Humidity Transmitters for HVAC are available with either a display opening or a solid f

Página 45

137Spare Parts and AccessoriesCO2 module GM10SPTemperature Module (CO2+T models) TM10SP Humidity and Temperature Module (CO2+T+RH models) HTM10SPDe

Página 46

12Vaisala HUMICAP® Humidity and Temperature Transmitter Series HMT330 is a flexible product family designed for demanding industrial applications.clea

Página 47

DimensionsDimensions in mm 29.8 47.5 5 9 59.5 34 33.5 30.5 27 Ø 4.4 132.7 30 81 Ref. B211296EN-B ©Vaisala 2014This material is subject to

Página 48 - Maintenance

139Decorative Cover for Vaisala GMW90 and HMW90 Series TransmittersThe decorative cover helps to camouflage the transmitter to the surroundings. Tran

Página 49

www.vaisala.com140GMW116 Carbon Dioxide and Temperature Transmitter for Ventilation ControlThe Vaisala CARBOCAP® Carbon Dioxide and Temperature Transm

Página 50 - Reliable Operation

141Technical DataPerformanceCO2-measurement range 0 ... 2000 ppm Temperature measurement range 0 ... +50 °CAccuracy (including repeatability, non-lin

Página 51

www.vaisala.com142GMW115 Carbon Dioxide Transmitter for Demand Controlled VentilationThe Vaisala CARBOCAP® Carbon Dioxide Transmitter GMW115 is a wall

Página 52

143Technical Data66.36060Ø 4.266.785.383.485.2R2.1124120.925.884R3.5PerformanceCO2-measurement range 0 ... 2000 ppm0...5000 ppmAccuracy (including r

Página 53

www.vaisala.com144GMD/W20 Series Carbon Dioxide Transmitters for Demand Controlled Ventilation ApplicationsThe duct mounted Vaisala CARBOCAP® Carbon D

Página 54 - Low Maintenance

145PerformanceCARBON DIOXIDE MEASUREMENTMeasurement range 0 ... 2000 ppm(nominal; can be calibrated for other ranges:0 ... 5000 ppm, 0 ... 10,000 ppm,

Página 55

www.vaisala.com146GMM112 Carbon Dioxide Module for HVAC ApplicationsThe Vaisala CARBOCAP® Carbon Dioxide Module GMM112 is a basic CO2 measurement modu

Página 56 - Chambers

147Technical DatamAV0BA024VmAV0BA024V25656306096Ø3.2PerformanceCO2-measurement range 0 ... 2000 ppm0 ... 5000 ppm0 ... 10000 ppmAccuracy (including re

Página 57

13Vaisala Humidity Calibrator HMK15 for multi-point on-site calibrations.Humidity Instrument CalibrationIn calibration, the humidity reading of an ins

Página 58 - Probe HMP60

148Pressure/ TECHNOLOGY DESCRIPTIONVaisala BAROCAP® Sensor for Measuring PressureBAROCAP in Brief ▪Over 25 years of accurate pressure measurement▪Sili

Página 59

149For more information, visitwww.vaisala.com or contact us at [email protected]. B210845EN-B ©Vaisala 2012This material is subject to copyright pr

Página 60 - Probe HMP110

www.vaisala.com150PTU300 Combined Pressure, Humidity and Temperature Transmitter for Demanding ApplicationsThe Vaisala Combined Pressure, Humidity and

Página 61

151PressurePTU300 ModelsDimensionsDimensions in mm (inches) PTU301 for wall mounting12 (0.47) 120 (4.72) PTU301 short cable probe with optional WLANDi

Página 62 - MI70 Link

152PTU300 ModelsPTU307 warmed probe for demanding meteorological installations37.5 (1.48) 79.5 (3.13) 99.5 (3.92) M9x1 Ø 12 (0.47) Ø 3.2 (0.13

Página 63

153Technical DataPressurePerformanceBAROMETRIC PRESSUREPressure range 500 ... 1100 hPa, 50 ... 1100 hPaAccuracy 500 ... 1100 hPa 500 ... 1100 hPa 50 .

Página 64 - Temperature Meter HM40

154MechanicsCable bushing M20 x 1.5 for cable diameter 8 ... 11 mm/0.31 ... 0.43"Conduit fitting 1/2" NPTUser cable connector (optional) M1

Página 65

155 Products, spare parts and accessories Convenient product comparison tool Invoice option (30 days NET)store.vaisala.com Pressure

Página 66

www.vaisala.com156PTB330 Digital Barometer for Professional Meteorology, Aviation, and Industrial UsersVaisala BAROCAP® Digital Barometer PTB330 is a

Página 67

157Technical DataPressureRef. B210708EN-E ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and i

Página 68

www.vaisala.com14HMT330 Series Humidity and Temperature Transmitters for Demanding Humidity MeasurementThe Vaisala HUMICAP® Humidity and Temperature T

Página 69

www.vaisala.com158Dimensional Drawings of the PTB330 Digital BarometerDimensionsDimensions in mm (inches)Mounting with Wall Mounting KitMounting with

Página 70 - Standard Contents of SHM40

159Get the latest news about technology, application solutions, instrumentation, and measurement practices.» Subscribe at www.vaisala.com/knowledgeInd

Página 71

www.vaisala.com160Operational PTB330TS unit includes a PTB330 digital barometer, hand-held MI70 indicator, optional HMP155 humidity and temperature pr

Página 72 - HMK15 Humidity Calibrator

161The PTB330 Digital BarometerThe HMP155 probe The MI70 hand-held indicator displaying the prevailing pressure in hPaPTB330 Digital Barometer Vaisal

Página 73

www.vaisala.com162Vaisala Barometric Pressure Transfer Standard PTB330TSPerformanceBarometric Pressure (PTB330)Measurement range 500 ... 1100 hPaLinea

Página 74

163Technical Data-20 0 20 40-0,3-0,2-0,100,30,20,1∆ °C°CInputs and OutputsMI70 probe ports 2MI70 data interface RS-232 (accessible only with MI70 Lin

Página 75

www.vaisala.com164PTB210 Digital BarometerFor Harsh EnvironmentsThe Vaisala BAROCAP® Digital Barometer PTB210 is ideal for outdoor installations and h

Página 76 - Precipitation Shields

165Technical DataOperating Range (1hPa=1mbar)Pressure range (order specified)serial output 500 ... 1100 hPa50 ... 1100 hPa analog output 500 ... 1100

Página 77

www.vaisala.com166PTB110 Barometer for Industrial UsePTB110The Vaisala BAROCAP® Barometer PTB110 is designed both for accurate barometric pressure mea

Página 78

167Technical DataOperating Range (1 hPa=1mbar)Pressure ranges 500 ... 1100 hPa600 ... 1100 hPa800 ... 1100 hPa800 ... 1060 hPa600 ... 1060 hPaTemperat

Página 79

15HumidityWide Range of Installation Options The wide variety of measurement probes, several installation accessories, and universal mains and DC powe

Página 80

www.vaisala.com168SPH10/20 Static Pressure Heads for Minimizing Wind Induced ErrorWind induced effects are one of the main sources of error when measu

Página 81

169Technical DataGeneralOperating temperature -60 ... +80 °C (-76 ... +176 °F)WeightSPH10 800 gSPH20 1360 gMaterial PC plastic, offshore aluminiumMoun

Página 82

www.vaisala.com170Vaisala Differential Pressure Transmitter PDT102 Vaisala Differential Pressure Transmitter PDT102 with process valve actuator and te

Página 83 - Glass substrate

171Technical DataRef. B211083EN-D ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its indiv

Página 84

www.vaisala.com172Vaisala Differential Pressure Transmitter PDT101 Vaisala Differential Pressure Transmitter PDT101 with current output (black) and vo

Página 85 - Data Collection

173Technical DataRef. B211082EN-D ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its indiv

Página 86 - Probe Specifications

174Weather/ TECHNOLOGY DESCRIPTIONVaisala Wind and Weather Sensor Technologies for Measurements in Industrial ApplicationsVaisala's long history

Página 87

175Vaisala Sensor Technologies for Wind and Rain Measurements Vaisala WINDCAP® SensorVaisala WINDCAP® Ultrasonic Wind Sensor uses ultrasound to determ

Página 88

www.vaisala.com176Vaisala Weather Transmitter WXT520 Access to Real Time Weather DataThe WXT520 has an automatic control circuit that switches the hea

Página 89 - We Make Sure It’s Dry

177Technical DataWeatherPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationBarometric PressureRange 600

Página 90 - DMT345: Accurate in Hot

16Technical Data °C°C00-80 -60 -40 -20 20 40 60 80 100 120 140 160180-0.7-0.6-0.5-0.4-0.3-0.2-0.10.10.20.30.40.50.60.7Temperature sensor Pt100 RTD Cla

Página 91

www.vaisala.com178WMT52 Ultrasonic Wind SensorProven Vaisala PerformanceThe Vaisala WINDCAP® Ultrasonic Wind Sensor WMT52 incorporates decades of Vais

Página 92

179Technical DataWeatherWindWIND SPEEDRange 0 ... 60 m/sResponse time 250 msAvailable variables average, maximum, and minimumAccuracy ±3% at 10m/s Out

Página 93

www.vaisala.com180WA15 Wind Set for High Performance Wind MeasurementWith a proven track record of successful installations, the Vaisala Wind Set WA15

Página 94 - OEM Applications

181Technical DataVaisala Anemometer WAA151Wind SpeedMeasurement range 0.4 ... 75 m/sStarting threshold < 0.5 m/s *Distance constant 2.0 mCharacteri

Página 95

182Vaisala Service OfferingAllParametersCalibratedOur global service centers calibrate all parametersand can meet yourspecific needs.RelativeHumidityTe

Página 96

183 Service OfferingCalibration Maintains and Documents AccuracyVancouver,CanadaBoston,USASão Paulo,BrazilHelsinki,FinlandBeijing,China Relative Humid

Página 97

184Vaisala FiltersVaisala FiltersGroup A: 12 mm Diameter, Standard Length, Female Threads62216221Plastic grid, 2 mm protection, ø 12.0 mmUse with: HM

Página 98

185 Service Offering230602 231865Group C: 12 mm Diameter, Male ThreadsHM46670SPHM46670SPSintered stainless steel filter, 38 µm, ø 12.0 mm Use with:

Página 99

17Ref. B210951EN-E ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners.

Página 100 - DMT132 Dewpoint Transmitter

www.vaisala.com/[email protected] measurements for humidity, temperature, dew point, carbon dioxide, pressure and moisture in oilIf

Página 101 - Technical Data

18HMT331 Humidity and Temperature Transmitter for Demanding Wall-Mounted ApplicationsThe Vaisala HUMICAP® Humidity and Temperature Transmitter HMT331

Página 102 - Spot-Checking Applications

19The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT334 is designed for humidity measurement in pressurized spaces or vacuum chambers. Ever

Página 103

20The Vaisala HUMICAP® Humidity and Temperature Transmitter HMT337 is delivered in one of three configurations:• Basic,withanon-warmedprobeform

Página 104 - Pressurized Processes

21HumidityThe Vaisala HUMICAP® Humidity and Temperature Transmitter HMT338 is designed for pressurized processes.Insert or Remove the Probe while the

Página 105

22HMT331 probe37.5 (1.48)78.5 (3.09)98.5 (3.88)Ø 12 (0.47)M9x1HMT333 probeM22×1.5 orNPT 1/2"120 (4.72)170 (6.69)41 (1.61)ø12 (0.47)HMT334 probe4

Página 106 - Dimensions

23HumidityThe quality and profitability of your process equals the quality of your measurement.The success of critical operations depends on small thin

Página 107

www.vaisala.com24HMT360 Series Intrinsically Safe Humidity and Temperature TransmittersThe Vaisala HUMICAP® Humidity and Temperature Transmitter Serie

Página 108 - The Fruit of Experience

25Interchangeable Probes for HMT360 Intrinsically Safe Humidity and Temperature TransmitterHumidityDimensionsDimensions in mm (inches) DimensionsDime

Página 109

26DimensionsDimensions in mm (inches) DimensionsDimensions in mm (inches) DimensionsDimensions in mm (inches) Technical DataHMP365 for high temperatur

Página 110 - Multiparameter Transmitter

27Technical DataHumidityPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 % RHAccuracy (including non-linearity, hysteresis, and repeatability)w

Página 111 - So Should Monitoring

1Demanding measurement requirements across multiple industries, from semiconductor to automotive to power, have always inspired Vaisala to continuousl

Página 112 - Moisture in Oil

28115 (4.53)164 (6.46)125 (4.92)39 (1.5)73 (2.9)11 (0.43) 62 (2.4)Classification with Current OutputsEUROPE / VTTEU (94/9/EC, ATEX100a) II 1 G

Página 113 - HUMICAP in Brief

29HumidityRef. B210956EN-C ©Vaisala 2014This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual p

Página 114 - Transmitter Series for Oil

www.vaisala.com30HMT310 Humidity and Temperature Transmitter Reliable Vaisala HUMICAP® TechnologyThe HMT310 incorporates the latest generation Vaisala

Página 115 - Mounting Options

31Technical DataHumidityΔ °C°C-0.70.70.60.50.40.30.20.1-0.1-0.2-0.3-0.4-0.5-0.600-60 -40 -20 20 40 60 80 100120140160180-80Electrical ConnectionsTwo a

Página 116 - MMT337 with Small-Sized Probe

32Ref. B210769EN-F ©Vaisala 2014This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual partners.

Página 117

33Calculate and Convert.www.vaisala.com/humiditycalculatorAvailable also as: The free web based Vaisala Humidity Calculator allows you to calculate s

Página 118 - Transmitter for Oil

www.vaisala.com34Vaisala HUMICAP® Humidity and Temperature Transmitters HMT120 and HMT130 The Vaisala HUMICAP® Humidity and Temperature Transmitters H

Página 119

35Technical DataHumidityPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracy including non-linearity, hysteresis, and repeatabilitytemp

Página 120

36145721201164639M4; 4 pcs919278Wall Assembly dimensions Remote probe dimensionsø12 [0,47]71 [2,8]Ref. B21 1086EN-E ©Vaisala 2013This material is subj

Página 121

37Humidity

Página 122

2Table of Contents by ParametersHumidityVaisala HUMICAP® Sensor for Measuring Relative Humidity ...

Página 123

www.vaisala.com38HMW90 Series Humidity and Temperature Transmitters for High Performance HVAC Applications Wall-mounted Vaisala HMW90 Series HUMICAP®

Página 124 - Carbon Dioxide

39Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityRef. B211183EN-D ©Vaisala 20

Página 125 - The CARBOCAP® Story

www.vaisala.com40HMD60/70 Humidity and Temperature Transmitters for Ducts in HVAC ApplicationsMeasures both Humidity and TemperatureThe HMD60 and HMD7

Página 126 - Measurements

41Technical DataRef. B210839EN-B ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi

Página 127

www.vaisala.com42HMDW110 Series Humidity and Temperature Transmitters for High-Accuracy Measurements in HVAC ApplicationsHMDW110 Series Humidity and T

Página 128 - Carbon Dioxide Probe

43HumidityHMW110/112 RH+T transmitters for measurements in wet areasHMD110/112 RH+T transmitters for ductsHMS110/112 RH+T transmitters for outdoor mea

Página 129 - Stability and Ability

44ModelsModel number Type Output Special Features Ingress ProtectionHMW110 Wall-mount, RH+T 2-wire, current output Configurable model* IP65 HMW112 Wal

Página 130 - Interchangeable Probes

45Find out more at www.vaisala.com/HVACHumidity

Página 131

www.vaisala.com46HMS110 Series Humidity and Temperature Transmitters for High-Accuracy Outdoor Measurements in Building Automation ApplicationsVaisala

Página 132 - Demanding OEM Applications

47Technical DataPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracyTemperature range +10 ... +30 °C (+50 ... +86 °F)0 ... 90 %RH ±2 %R

Página 133

3Pressure Dew PointMoisture in OilCarbon Dioxide HumidityWeather S OfferingMoisture in Oil Vaisala HUMICAP® Sensor for Measuring Moisture in Oil ...

Página 134 - GMM111 Carbon Dioxide Module

www.vaisala.com48HMDW80 Series Humidity and Temperature Transmitters for Building Automation Applications HMDW80 Series Humidity and Temperature Tran

Página 135

49HumidityHMW88/89(D) RH+T transmitters for measurements in wet areas 76.9123.7955.581127.360.359Ø4.4Ø4.42032.424HMW82/83 RH+T and TMW82/83 T-only

Página 136 - Two Sampling Methods

50Technical DataModelsModel number Type Output Special Features Ingress ProtectionTMW82 Wall-mount, T-only 2-wire, current output IP30TMW83 Wall-mount

Página 137

51HumidityRef. B211253EN-B ©Vaisala 2013This material is subject to copyright protection, with all copyrights retained by Vaisala and its individual p

Página 138 - Easy Calibration

www.vaisala.com52HMS80 Series Humidity and Temperature Transmitters for Outdoor Measurements in Building Automation ApplicationsVaisala INTERCAP® Humi

Página 139

53HumidityTechnical DataPerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHAccuracyTemperature range +10 ... +30 °C (+50 ... +86 °F)0 ... 90 %

Página 140 - Please contact us at

www.vaisala.com54HMM100 Humidity Module for Environmental Chambers The Vaisala HUMICAP® Humidity Module HMM100 is an open frame module for integration

Página 141

55Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityMechanicsService cable conne

Página 142

www.vaisala.com56Vaisala INTERCAP® Humidity and Temperature Probe HMP60HMP60The HMP60 is a simple, durable and cost-effective humidity probe. It is su

Página 143

57Technical Data PerformanceRELATIVE HUMIDITYMeasurement range 0 ... 100 %RHTypical accuracy temperature range 0 ... +40 °C0 ... 90 %RH ±3 %RH90 ...

Página 144 - Demand Controlled Ventilation

4Humidity/ TECHNOLOGY DESCRIPTIONVaisala HUMICAP® Sensor for Measuring Relative HumidityIn 1973, Vaisala introduced HUMICAP®, the world’s first thin-fil

Página 145

www.vaisala.com58Vaisala HUMICAP® Humidity and Temperature Probe HMP110The HMP110 is a trouble-free and cost-effective humidity transmitter with high

Página 146

59Technical Data Please contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityPerformanceRELATIVE HUMIDIT

Página 147

www.vaisala.com60HM70 Hand-Held Humidity and Temperature Meter for Spot-Checking ApplicationsThe Vaisala HUMICAP® Hand-Held Humidity and Temperature M

Página 148 - GMM112 Carbon Dioxide Module

61Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidity °C°C00-80 -60 -40 -20 20 40

Página 149

www.vaisala.com62Vaisala HUMICAP® Hand-Held Humidity and Temperature Meter HM40 The HM40 is a compact and portable humidity meter at hand everywhere y

Página 150 - Pressure

63Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationPerformanceRELATIVE HUMIDITYMeasurem

Página 151 - The BAROCAP Story

www.vaisala.com64HMI41 Indicator and HMP42/HMP46 ProbesThe Vaisala HUMICAP® Humidity Indicator HMI41 fitted with the Vaisala HUMICAP® Humidity and Tem

Página 152

65Technical DataHMI41 IndicatorCalculated variables dew point temperature, absolute humidity,wet bulb temperature, mixing ratioResolution 0.1 %RH; 0.

Página 153 - PTU300 Models

66Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationAccessoriesTransmitter calibration c

Página 154

67Get the latest news about technology, application solutions, instrumentation, and measurement practices.» Subscribe at www.vaisala.com/knowledgeIndu

Página 155

5For more information, visitwww.vaisala.com or contact us at [email protected]. B210781EN-C ©Vaisala 2012This material is subject to copyright prot

Página 156

www.vaisala.com68SHM40 Structural Humidity Measurement Kit SHM40 Structural Humidity Measurement Kit Vaisala HUMICAP® Structural Humidity Measurement

Página 157

69Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityTemperatureMeasurement range

Página 158

www.vaisala.com70HMK15 Humidity CalibratorNo measuring instrument stays accurate by itself. It is essential that the functioning of an instrument is p

Página 159

71Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationHumidityGeneralThe standard HMK15 co

Página 160 - Digital Barometer

www.vaisala.com72HMP155 Humidity and Temperature ProbeHMP155 with an additional temperature probe and optional Stevenson screen installation kit. Fea

Página 161 - SUBSCRIBE

73Technical DataRef. B210752EN-E ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi

Página 162 - Take the Lab to the Field

www.vaisala.com74DTR500 Solar Radiation and Precipitation ShieldsThe Vaisala Solar Radiation Shield Series DTR500 are available in either a 5-, 9- or

Página 163

75Technical DataRef. B210906EN-D ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi

Página 164 - Standard PTB330TS

www.vaisala.com76HMT330MIK Meteorological Installation Kit10095908580751234 56 7warmed proberegular probe The Vaisala Meteorological Installation Kit

Página 165

77Technical DataRef. B210944EN-D ©Vaisala 2012This material is subject to copyright protection, with all copyrights retained by Vaisala and its indivi

Página 166 - PTB210 Digital Barometer

6How to Choose the Right Instrument for Measuring Humidity and Dew PointPartial Pressure of Water VaporHumidity is simply water in its gaseous phase,

Página 167

www.vaisala.com78HMT300TMK Turbine Mounting Kit for Power Turbine Intake Air MeasurementThe Vaisala HUMICAP® Turbine Mounting Kit HMT300TMK is develop

Página 168 - Applications

79Technical Data91.5 (3.6)165.3 (6.51)354.9 (13.97)488 (19.21)193 (7.6)254 (10)203 (8)441.5 (17.38)144.5 (5.69)101.6 (4)100 (3.94)100 (3.94)Ø13 (0.51)

Página 169

80/ TECHNOLOGY DESCRIPTIONVaisala DRYCAP® Sensor for Measuring Dew PointDRYCAP in Brief ▪Thin-film polymer sensor withunique auto-calibration function

Página 170 - Carefree Maintenance

81For more information, visitwww.vaisala.com or contact us at [email protected]. B210981EN-B ©Vaisala 2012This material is subject to copyright pro

Página 171

www.vaisala.com82DMT340 Series Dewpoint and Temperature Transmitters for Very Dry ConditionsThe Vaisala DRYCAP® Dewpoint and Temperature Transmitter S

Página 172 - Available Options

83Dew PointNPT 1/2"17041120Ø 12M22x1.5 or(6.69)(4.72)(1.61)(0.47)The display alarm allows tracking of any measured parameter, with freely configu

Página 173

84ØØ/ 448 (17.6) / 410 (16.1) 41 (1.61) - 149 (5.87) / 41 (1.61) - 379 (14.9)191 (7.52) 215.5 (8.48) 41 (1.61)12 (0.47) 13.5 (0.53)R1/2” ISO7/1 35 (1.

Página 174

85Technical DataDew PointArea not recommended for continuous measurementDew point measurement renge lower limitDew point temperature (°C)Temperature o

Página 175

86Please contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more information16996116183Ø77771(2.80)(3.03)(7.20)(6.65)(4.57)(3.

Página 176 - / TECHNOLOGY DESCRIPTION

87Fastest wet-to-dry response time on the market - just minutesProduct range from -80°C to +60°C Td with ±2°C accuracy Long, 2-year calibration inte

Página 177 - Vaisala RAINCAP® Sensor

7If saturation vapor pressure is reached in air or in a gas mixture, the introduction of additional water vapor requires that an equal amount condense

Página 178 - Precipitation

www.vaisala.com88DMT345 and DMT346 Dewpoint Transmitters for High Temperature ApplicationsThe Vaisala DRYCAP® Dewpoint Transmitters DMT345 and DMT346

Página 179

89Dew PointTechnical DataMeasured Variables DMT345DEW POINT DMT345Sensor Vaisala DRYCAP®180SMeasurement range -40 ... +100 °C (-40 ... +212 °F) TdAccu

Página 180 - WMT52 Ultrasonic Wind Sensor

90Technical DataOperating Environment, DMT345 and DMT346 Mechanical durability up to +180 °C (+356 °F) for DMT345of probes up to +350 °C (+662 °F) for

Página 181

91Technical DataPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationDew PointDimensionsDimensions in mm

Página 182 - Wind Measurement

www.vaisala.com92DMT242 Dewpoint Transmitter for OEM ApplicationsDue to its wide measurement range and high long-term stability, the DMT242 is an ide

Página 183

93Technical Data Dew point temperature (°C)020 40 60040-60-80Process temperature (°C)102030506070-10-20-30-50-40-70301050Accuracy < ± 2°C TdDew poi

Página 184 - Vaisala Service Offering

www.vaisala.com94DMT152 Dewpoint Transmitter for Low Dew Point Measurement in OEM Applications The Vaisala DRYCAP® DewpointTransmitter DMT152 is desig

Página 185 - Service Offering

95Technical DataDew PointPlease contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationTechnical DataMeasured Vari

Página 186

www.vaisala.com96DMT143 Miniature Dewpoint Transmitter for OEM ApplicationsTechnical DataFeatures/Benefits▪Miniature size dew point transmitter for e.g

Página 187

97Please contact us at www.vaisala.com/requestinfowww.vaisala.com Scan the code for more informationTechnical DataDew PointMeasured Parameters DEW PO