Chapter 3 _______________________________________________________________ Installation
VAISALA_______________________________________________________________________ 27
0506-017
Figure 10 Power Supply and Mount
Connecting Lightning Ground
Connect the existing ground wire to the threaded ground stud at the
bottom left of the power supply with the provided lock washer and nut
found in the mounting kit assembly.
The following numbers refer to Figure 10 on page 27:
1 = WS425PowerUS or WS425PowerEU power supply
2 = Power supply mounting plate
3 = Pole mast installation plate (not provided by Vaisala)
4 = Pole mast (not provided by Vaisala)