In applications where adverse electromagnetic fields exist, an
additional EMI protection may be necessary. In Figure 3, there is an
example of an electromagnetic interference protection of the PMB100
module. The EMI filters should be placed as close to the pins as
possible.
Power
regulator
+
-
V
out
filter
filter
filter
GND
V
ref
PMB100 module
Copper pour connected to ground.
GND directly connected
to ground plane
OUT
VDC
REF
V
out
V
ref
VDC
GND
Figure 3 Electromagnetic interference protection of the
PMB100. Filters, for example, T-type EMI
suppression filters with capacitance of 47pF (like
Murata, DSS310-55Y5S470M100). This connection
setup fulfills the RF field immunity standard
EN61000-4-3.