3. For each log item, select the following options in the Log item
options frame:
- Save this item each time its value changes
- Autonomous data source
4. In the Log groups list, set the Interval to zero.
To see the user interactions, for example, from the service
connection, type the following:
logshow <group_id> [YYMMDDhhmmss] [count]
/Log > logshow L0 050510180100 6
AdclShell:shell_log
2005-05-10 18:01:02 V-----
In: Session started
2005-05-10 18:01:02 V-----
In:
2005-05-10 18:01:03 V-----
In: dir
2005-05-10 18:01:07 V-----
In: cd /Log
2005-05-10 18:01:08 V-----
In: dir
2005-05-10 18:01:11 V-----
In: logshow L0