Vaisala Humicap HMD60Y Manual do Utilizador

Consulte online ou descarregue Manual do Utilizador para Componentes para dispositivos de segurança Vaisala Humicap HMD60Y. HMD60 Users Guide in English Manual do Utilizador

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
  • Página
    / 18
  • Índice
  • MARCADORES
  • Avaliado. / 5. Com base em avaliações de clientes
Vista de página 0
USER'S GUIDE
Vaisala HUMICAP
®
Humidity and
Temperature Transmitters
HMD60U/Y
U301EN11
Vista de página 0
1 2 3 4 5 6 ... 17 18

Resumo do Conteúdo

Página 1 - USER'S GUIDE

USER'S GUIDE Vaisala HUMICAP® Humidity and Temperature TransmittersHMD60U/Y U301EN11

Página 2

HMD60U/Y TransmittersOperating Manual U301en-1.16 1997-07-313.5 Electronics10528HM18941HMGLANDS LIDSCREW TERMINALSCREWSMEMBRANE FILTER part no. 17039

Página 3 - Contents

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 74. CALIBRATION4.1 One-point humidity calibrationThe accuracy is recommended to be checked

Página 4

HMD60U/Y TransmittersOperating Manual U301en-1.18 1997-07-314.3 Calibration tableTemperature °C 15 20 25 30 35°F 59 68 77 86 95LiCl %RH *) 11.3 11.3 1

Página 5 - 1. PRODUCT DESCRIPTION

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 96. TECHNICAL DATA6.1 Relative humidityMeasurement range 0...100 %RHAccuracy at +20 °C:10 4

Página 6 - 2 1997-07-31

HMD60U/Y TransmittersOperating Manual U301en-1.110 1997-07-316.3 GeneralSupply voltage 10...35 VDC (RL= 0Ω)20...35 VDC (RL=500Ω)Output signal 4...20 m

Página 7 - 3. INSTALLATION

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 116.4 Electromagnetic compatibilityThe emission and immunity tests have been performed acco

Página 11 - 4. CALIBRATION

PUBLISHED BY Vaisala Oyj Phone (int.): +358 9 8949 1 P.O. Box 26 Fax: +358 9 8949 2227 FIN-00421 Helsinki Finland Visit our Internet pages at ht

Página 12 - 5. MAINTENANCE

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 iContents1. PRODUCT DESCRIPTION ...

Página 13 - 6. TECHNICAL DATA

HMD60U/Y TransmittersOperating Manual U301en-1.1ii 1997-07-31This page intentionally left blank.

Página 14 - 10 1997-07-31

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 11. PRODUCT DESCRIPTIONThe HMD60 transmitters are duct mounted two-wire transmitters for th

Página 15 - U301en-1.1 Operating Manual

HMD60U/Y TransmittersOperating Manual U301en-1.12 1997-07-312. TO BE NOTED WHEN MEASURING HUMIDITYIn the measurement of humidity and especially in cal

Página 16

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 33. INSTALLATION3.1 Selecting the place of installationSelect a place that gives a true pic

Página 17

HMD60U/Y TransmittersOperating Manual U301en-1.14 1997-07-313.3 GroundingOpen the lid and mount the cable bushing set 18941HM. Do the groundingaccordi

Página 18

HMD60U/Y TransmittersU301en-1.1 Operating Manual1997-07-31 53.4 Electrical connectionsConnect the signal cables to a removeable 5-pole screw connector

Comentários a estes Manuais

Sem comentários